RCSL Corrosion Monitoring
Model ER7200 – Electrical Resistance Probe
The ER7200 places a flush ER element at the pipe wall through a two-inch access system. Fixed-length construction supports high-pressure applications and retrieval without process shutdown using suitable tools.
Product information
View Model ER7200 – Electrical Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
| Specification | Catalogue value |
|---|---|
| Probe Body | 316 Stainless Steel |
| Element Seal | Epoxy |
| Fill Material | Epoxy |
| Temperature Rating | 260°C / 500°F |
| Pressure Rating | 3600 PSI / 245 Barg |
| Mounting | Two Inch Access Fitting System With Hollow Plug |
Element options
| Ordering option code | Element and useful life |
|---|---|
| A | S4 Flush Mount – 4 mil thickness (2 mil useful probe life) |
| B | S8 Flush Mount – 8 mil thickness (4 mil useful probe life) |
| H | S20 Flush Mount – 20 mil thickness (10 mil useful probe life) |
Replacement parts
| Part | Product code |
|---|---|
| PTFE probe seal | 700277 |
| PEEK probe seal | 700339 |
| 316 stainless-steel hollow-plug bore-seal nut | 700311 |
Application and installation notes
- The probe mounts into the hollow plug of a two-inch access fitting. A compatible retriever and service valve allow installation without process shutdown. Probe adaptors are ordered separately.
- Catalogue minimum insertion length: 1.75 inches. Longer lengths are specified in ⅛-inch increments.
Element alloy options in the catalogue include carbon steel, 5Cr ½Mo, 9Cr 1Mo, 410 stainless, 304 stainless, 316L stainless, C276, Alloy 625, CDA110 and CDA443. Not every alloy is available with every element type or seal.
Source: RCSL Product Catalogue 2019, PDF pages 70, 71. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.