RCSL Corrosion Monitoring
Injection and Sampling System
Two-inch injection and sampling systems deliver treatment chemicals or collect process-fluid samples for analysis. Configurations range from open tubes to atomising heads for petroleum, chemical and water-treatment applications.
Product information
View Injection and Sampling System on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
The two-inch retrievable system comprises a tee access fitting, solid plug, injection/sampling nut, tube or nozzle, and the appropriate nipple, shut-off valve and optional check valve. Standard nut, quill, nipple and valve material is 316 stainless steel; standard nut sealing uses one Viton O-ring and two PTFE backup rings.
| Tube type | Selection purpose |
|---|---|
| X Open | Open-ended tube using process turbulence; injection rate controlled at pump or shut-off valve |
| X Quill | Scarf/quill end promotes dispersion; the catalogue specifies good dispersion at product velocity of 4.6 m/s or greater |
| X NPT | Threaded end accepts a compatible nozzle assembly |
| X Head | Integral head takes cap/core components for atomised injection |
Selection depends on injection rate, pump-to-process pressure differential, temperature, viscosity, specific gravity, spray angle and coverage. The catalogue describes available injection rates from 0.38 to 250 litres/hour. Centre-line injection generally uses the highest fluid velocity; a flush arrangement may be required where pigging prevents a projecting tube. Sampling tubes normally have a straight-cut rather than scarf-cut end.
| Ordering parameter | Catalogue options |
|---|---|
| Tube/NPT sizes | 1/8, 1/4, 1/2 or 3/4 inch |
| Open/quill/NPT tube lengths | 1.25 to 30 inches |
| X Head lengths | 2.25 to 30 inches |
| Length increments | 1/8 inch |
| Tube schedules | 80, 160, XXS or specified alternative |
| Shut-off valve NPT sizes | 1/4, 1/2, 3/4 or 1 inch |
| Valve pressure options | 6000 or 10000 psi, selected separately from complete-system rating |
Not every material, size and schedule combination is available. Nozzle-capacity values below are reproduced in the catalogue’s GPH units at the stated pressure differential; they are not a complete-system pressure rating.
| Product code(s) | Nozzle style | 40 psi GPH | 60 psi GPH | 80 psi GPH | 100 psi GPH |
|---|---|---|---|---|---|
| 700030 /700034 /700038 | 0.30; female NPT / flush / cap-core | 0.3 | 0.36 | 0.42 | 0.48 |
| 700031 /700035 /700039 | 0.40; female NPT / flush / cap-core | 0.4 | 0.48 | 0.56 | 0.64 |
| 700032 /700036 /700040 | 0.60; female NPT / flush / cap-core | 0.6 | 0.72 | 0.84 | 0.96 |
Source: RCSL Product Catalogue 2019, PDF pages 151, 152, 153, 154, 155. Confirm current specifications and the complete assembly configuration before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.