RCSL Corrosion Monitoring
Model ER6000 – Electrical Resistance Probe
The ER6000 is a fixed-length, flange-mounted probe with a loop element for high-pressure or hazardous installations. It offers selectable flanges and insertion lengths, with shutdown or isolation required for inspection.
Product information
View Model ER6000 – Electrical Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
| Specification | Catalogue value |
|---|---|
| Probe Body Material | 316 Stainless Steel |
| Element Seal | Glass or Teflon |
| Fill Material | Ceramic |
| Temperature Rating | 260°C / 500°F Teflon® |
| Pressure Rating | Per flange pressure rating |
| Mounting | Flanged branch |
Standard lengths
| Order length (inches) | Maximum insertion length (inches) |
|---|---|
| 8" | 6.125" |
| 12" | 10.125" |
| 18" | 16.125" |
| 24" | 22.125" |
Element options
| Ordering option code | Element and useful life |
|---|---|
| 0 | WR40 Wire Loop – 40 mil thickness (10 mil useful probe life) |
| 1 | WR80 Wire Loop – 80 mil thickness (20 mil useful probe life) |
| 2 | TU04 Tube Loop – 4 mil thickness (2 mil useful probe life) |
| 3 | TU08 Tube Loop – 8 mil thickness (4 mil useful probe life) |
| 8 | SL05 Strip Loop – 5 mil thickness (1.25 mil useful probe life) |
| 9 | SL10 Strip Loop – 10 mil thickness (2.5 mil useful probe life) |
Application and installation notes
- Installation requires process isolation or shutdown. Confirm the connection and insertion length against the installation drawing.
Element alloy options in the catalogue include carbon steel, 5Cr ½Mo, 9Cr 1Mo, 410 stainless, 304 stainless, 316L stainless, C276, Alloy 625, CDA110 and CDA443. Not every alloy is available with every element type or seal.
Source: RCSL Product Catalogue 2019, PDF pages 60, 61. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.