RCSL Corrosion Monitoring
Model LP4100 – Linear Polarisation Resistance Probe
The LP4100 provides three-electrode LPR monitoring through a retractable packing-gland assembly. It supports insertion and withdrawal from pressurised process equipment, with selectable lengths and electrodes supplied separately.
Product information
View Model LP4100 – Linear Polarisation Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Specifications and selection information
| Property | Details |
|---|---|
| Body | 316 stainless steel or C276 |
| Seal / fill | Glass / epoxy |
| Packing | PTFE standard; Grafoil optional |
| Temperature | 260°C / 500°F with PTFE |
| Pressure | 2000 psi / 138 barg |
| Mounting | Minimum 1 inch full-bore valve |
| Electrodes | EL412XXX2800000; sold separately |
Packing gland, mechanical stop and adjustable safety chain support retractable installation. RCSL recommends the SR2159 Easy Tool for insertion/retraction above 150 psi. External piping/valve components and electrodes are separate. Electrode alloy changes electrode length. Refer to the complete system procedure before pressurised servicing.
Standard lengths
| Order length (inches) | Maximum insertion length (inches) |
|---|---|
| 24 | 17.53 |
| 30 | 23.53 |
| 36 | 29.53 |
| 42 | 35.53 |
Choose integral or plug-type mounting and the required packing. Optional safety-clamp code PS5463141XX uses XX for length.
Source: RCSL product catalogue, PDF pages 96, 97. Ratings depend on the selected configuration; confirm current suitability and documentation before ordering.