RCSL Corrosion Monitoring

Model LP7100 – Linear Polarisation Resistance Probe

The LP7100 is a fixed-length, three-electrode LPR probe for two-inch access systems. A hollow-plug mount enables retrieval under operating conditions, with separate probe adapters and a choice of electrodes.

RCSL Model LP7100 - Linear Polarisation Resistance Probe

Product information

View Model LP7100 – Linear Polarisation Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.

Specifications and selection information

Property Details
Body 316 stainless steel or C276
Seal / fill Glass / epoxy
Temperature 260°C / 500°F
Pressure 3600 psi / 245 bar
Mounting Two-inch access fitting with hollow plug
Connection 1-14 UNS 2A left-hand thread; six-pin connector
Insertion length From 2 inches, in ⅛ inch increments
Replacement electrodes EL412XXX2800000 for standard 5-40 UNC studs; sold separately

For CorrTran instruments order 4-40 UNC mounting studs and EL525XXX28000XX electrodes. Standard three-electrode mounting uses 5-40 UNC studs; alloy-dependent electrode length must be considered.

Compatible retrieval tool and service valve enable installation without shutdown. Probe adapters are ordered separately. Select mounting material, connector option, insertion length and PTFE or PEEK probe seal.

Replacement parts

Part Code
PTFE probe seal 700277
PEEK probe seal 700339
316 stainless hollow-plug bore-seal nut 700311

Source: RCSL product catalogue, PDF pages 106, 107. Ratings depend on the selected configuration; confirm current suitability and documentation before ordering.

Discuss your requirements

Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.

Contact Tremco Pipeline Equipment