RCSL Corrosion Monitoring

Electrical Resistance Probes and Accessories

Electrical-resistance probes measure corrosion through changes in sensing-element resistance. RCSL offers atmospheric, buried-service, direct-mounted, retractable and retrievable designs, together with cables, adapters, shields and safety accessories.

RCSL Electrical Resistance Probes and Accessories

Explore the range

Explore product information below. Manufacturer links provide additional technical details.

RCSL manufacturer category reference

Technical information and selection

Start with the service environment and access method, then select the sensing element, material, connection and insertion length. The models below have different pressure, temperature and installation limits; the family name alone does not establish suitability.

Access/application Models in this range Selection considerations
Atmospheric and buried service ER0250 / ER0500 Exposed atmospheric element or buried/structural monitoring; check body, cable and temperature selection.
Direct-mounted threaded probes ER1000 / ER2000 / ER2100 Fixed insertion length; installation requires isolation or shutdown.
Adjustable direct-mounted probes ER3000 / ER3100 / ER3110 / ER3200 Compression fitting adjusts insertion depth; mounting, body material and rating vary by model.
Retractable probes ER4000 / ER4100 / ER4200 / ER4210 Packing gland permits in-service withdrawal; select suitable valve, safety equipment and access clearance.
Flanged probes ER6000 / ER6100 / ER6200 Pressure capability follows the selected flange; installation requires isolation or shutdown.
Two-inch retrievable system ER7000 / ER7100 / ER7200 / ER7210 / ER7220 / ER7300 Uses hollow-plug access fitting, retriever and service valve; specify insertion depth and element.

Useful probe life depends on element geometry as well as thickness. Compare the element tables on each product page rather than assuming all probes use the same thickness-to-life ratio.

Source: RCSL Product Catalogue 2019, PDF pages 33, 34, 36, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 60, 62, 64, 66, 68, 70, 72, 74, 78. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.

Discuss your requirements

Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.

Contact Tremco Pipeline Equipment