RCSL Corrosion Monitoring
Corrosion Test Supplies for the Water Treating Industry
RCSL offers corrosion-test coupons tailored to water-treatment applications, with selectable material, size, shape and finish. Identification markings and optional pre-weighing and measurement help support consistent test records.
Product information
View Corrosion Test Supplies for the Water Treating Industry on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
Coupons may be alloy/sequence marked, pre-weighed and measured. Request material-composition mill reports when ordering. Surface-finish choices include mill finish, glass-bead blast, 120-grit finish and double-disc grinding; finer belt finishes up to 800 grit are available.
| Type code + alloy | Dimensions (in) | Hole detail (in) | Approx. area (in²) |
|---|---|---|---|
| 100 | 1/2 ×3 ×1/16 | 3/16; 1/4 from end | 3.38 |
| 101 | 1 ×2 ×1/16 | 3/16; 1/4 from end | 4.32 |
| 102 | 1/2 ×3 ×1/16 | 9/64; 1/8 from end | 3.41 |
| 103 | 1/2 ×3 ×1/16 | 1/4; 1/4 from end | 3.34 |
| 104 | 1/2 ×3 ×1/16 | Two1/4; 1/2 from end | 3.24 |
| 105 | 1/2 ×3 ×1/16 | 3/16; 1/2 from end | 3.38 |
| 106 | 1/2 ×3 ×1/16 | 1/4; 1/2 from end | 3.34 |
| 115 | 1/2 ×3 ×1/16 | 1/4; 1/4 from end | 3.34 |
| 117 | 3/8 ×3 ×1/16 | 9/64; 1/8 from end | 2.64 |
| 118 | 1/2 ×3 ×1/16 | Two1/4; 1/4 and 3/4 from end | 3.24 |
| 120 | 3/8 ×3 ×1/16 | Two1/4; 1/4 and 3/4 from end | 2.48 |
| 131 | 2 ×3/4 ×1/8 | 3/8 central | 3.47 |
| 146 | 2 ×1 ×1/16 | 53/200 central | 4.26 |
| 220 | 1¼ diameter ×1/8 | 3/8 central | 2.72 |
| Cylindrical coupon | Size (in) |
|---|---|
| ES200 | 1/4 ×2.5 |
| ES201 | 1/4 ×2 |
| ES202 | 1/4 ×3 |
| ES204 | 1/4 ×1.5 |
The cylindrical coupons are standard C1018, with 1/4-20 ×3/8-inch thread and 1/16-inch slot. Pipe-plug assemblies use carbon-steel or PVC plugs and standard 3-inch nylon or Teflon stems; select the assembly against the coupon code and mounting holes. Other plug sizes and stem lengths are available.
Source: RCSL Product Catalogue 2019, PDF pages 29, 30. Confirm current specifications and the complete assembly configuration before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.