RCSL Corrosion Monitoring
Model ER4200 – Electrical Resistance Probe
The ER4200 is a retractable ER probe with a small flush element for monitoring at the pipe wall. Its packing gland permits insertion or withdrawal while the process remains pressurised.
Product information
View Model ER4200 – Electrical Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
| Specification | Catalogue value |
|---|---|
| Probe Body Material | 316 Stainless Steel |
| Element Seal | Epoxy |
| Fill Material | Epoxy |
| Temperature Rating | 260°C / 500°F Teflon® |
| Pressure Rating | 2000 PSI / 138 Barg |
| Mounting | Minimum 1" Full Bore Valve |
Standard lengths
| Order length (inches) | Maximum insertion length (inches) |
|---|---|
| 24" | 16.22" |
| 30" | 22.22" |
| 36" | 28.22" |
| 42" | 34.22" |
Element options
| Ordering option code | Element and useful life |
|---|---|
| A0 | FS04 Flush Mount – 4 mil thickness (2 mil useful probe life) |
| B0 | FS08 Flush Mount – 8 mil thickness (4 mil useful probe life) |
| H0 | FS20 Flush Mount – 20 mil thickness (10 mil useful probe life) |
Application and installation notes
- The packing-gland arrangement permits insertion and retraction without a process shutdown. Safety chain and safety nut are provided; associated process connection equipment must be selected separately.
- The catalogue recommends the Easy Tool (SR2159-ERXX) for insertion or retraction above 150 psi. Other body materials are available.
Element alloy options in the catalogue include carbon steel, 5Cr ½Mo, 9Cr 1Mo, 410 stainless, 304 stainless, 316L stainless, C276, Alloy 625, CDA110 and CDA443. Not every alloy is available with every element type or seal.
Source: RCSL Product Catalogue 2019, PDF pages 54, 55. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.