RCSL Corrosion Monitoring
Model ER3200 – Electrical Resistance Probe
The ER3200 positions a flush ER element using an adjustable compression fitting and integral adapter. Customers can specify insertion length for threaded installations that permit process isolation or shutdown.
Product information
View Model ER3200 – Electrical Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
| Specification | Catalogue value |
|---|---|
| Probe Body | 316 Stainless Steel |
| Element Seal | Epoxy |
| Fill Material | Epoxy |
| Temperature Rating | 260°C / 500°F |
| Pressure Rating | 1500psi / 102 Bar |
| Mounting | 1½” NPT Fitting |
Insertion-length selection
| Length ordering code | Maximum insertion length (inches) |
|---|---|
| 06 | 3 |
| 08 | 5 |
| 12 | 9 |
| 18 | 15 |
Element options
| Ordering option code | Element and useful life |
|---|---|
| C03 | FL05 Flush Mount – 5 mil thickness (2.5 mil useful probe life) |
| D03 | FL10 Flush Mount – 10 mil thickness (5 mil useful probe life) |
| E03 | FL20 Flush Mount – 20 mil thickness (10 mil useful probe life) |
| F03 | FL40 Flush Mount – 40 mil thickness (20 mil useful probe life) |
Application and installation notes
- Installation requires process isolation or shutdown. Confirm the connection and insertion length against the installation drawing.
- The ¾-inch compression fitting is combined with a non-removable ¾-inch-to-1½-inch adaptor. Insertion length is measured to the element end.
Element alloy options in the catalogue include carbon steel, 5Cr ½Mo, 9Cr 1Mo, 410 stainless, 304 stainless, 316L stainless, C276, Alloy 625, CDA110 and CDA443. Not every alloy is available with every element type or seal.
Source: RCSL Product Catalogue 2019, PDF pages 48, 49. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.