RCSL Corrosion Monitoring
Model ER3110 – Electrical Resistance Probe
The ER3110 has an adjustable insertion length, cylindrical element and non-metallic body that electrically isolates the sensor from the vessel. This helps reduce measurement distortion associated with stray currents or galvanic effects.
Product information
View Model ER3110 – Electrical Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
| Specification | Catalogue value |
|---|---|
| Probe Body | Glass Epoxy |
| Element Seal | Epoxy |
| Fill Material | Epoxy |
| Temperature Rating (with Nylon Compression Fitting) | 65°C / 150°F |
| Pressure Rating | 100psi / 7 Bar |
| Mounting | ¾" NPT Pipe Plug |
Insertion-length selection
| Length ordering code | Maximum insertion length (inches) |
|---|---|
| 11 | 9.5 |
Element options
| Ordering option code | Element and useful life |
|---|---|
| 503 | CT10 Cylindrical – 10 mil thickness (5 mil useful probe life) |
| 603 | CT20 Cylindrical – 20 mil thickness (10 mil useful probe life) |
| 703 | CT50 Cylindrical – 50 mil thickness (25 mil useful probe life) |
Application and installation notes
- Installation requires process isolation or shutdown. Confirm the connection and insertion length against the installation drawing.
- The glass-epoxy body electrically isolates the sensing element from the vessel, reducing interference from galvanic effects or stray currents. Maximum insertion length is 9.5 inches.
Element alloy options in the catalogue include carbon steel, 5Cr ½Mo, 9Cr 1Mo, 410 stainless, 304 stainless, 316L stainless, C276, Alloy 625, CDA110 and CDA443. Not every alloy is available with every element type or seal.
Source: RCSL Product Catalogue 2019, PDF pages 46, 47. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.