RCSL Corrosion Monitoring
Model ER3000 – Electrical Resistance Probe
The ER3000 uses a compression fitting to set the required insertion length in threaded process connections. Its loop-element assembly includes a safety nut, with optional velocity shielding and installation during process isolation.
Product information
View Model ER3000 – Electrical Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Technical information and selection
| Specification | Catalogue value |
|---|---|
| Probe Body | 316 Stainless Steel |
| Element Seal | Glass or Teflon® |
| Fill Material | Ceramic |
| Temperature Rating | 260°C / 500°F |
| Pressure Rating | 1500psi / 102 Bar |
| Mounting | ¾" or 1" NPT Fitting |
Insertion-length selection
| Length ordering code | Maximum insertion length (inches) |
|---|---|
| 06 | 5.33 |
| 08 | 7.33 |
| 12 | 11.33 |
| 18 | 17.33 |
Element options
| Ordering option code | Element and useful life |
|---|---|
| 0 | WR40 Wire Loop – 40 mil thickness (10 mil useful probe life) |
| 10 | WR80 Wire Loop – 80 mil thickness (20 mil useful probe life) |
| 20 | TU04 Tube Loop – 4 mil thickness (2 mil useful probe life) |
| 30 | TU08 Tube Loop – 8 mil thickness (4 mil useful probe life) |
| 80 | SL05 Strip Loop – 5 mil thickness (1.25 mil useful probe life) |
| 90 | 10 mil loop element (2.5 mil useful probe life); confirm designation for option 90 |
| A0 | FS04 Flush Mount Small – 4 mil thickness (2 mil useful probe life) |
Application and installation notes
- Installation requires process isolation or shutdown. Confirm the connection and insertion length against the installation drawing.
- The compression fitting permits insertion-depth adjustment; the assembly includes a safety nut. A velocity shield is optional.
Element alloy options in the catalogue include carbon steel, 5Cr ½Mo, 9Cr 1Mo, 410 stainless, 304 stainless, 316L stainless, C276, Alloy 625, CDA110 and CDA443. Not every alloy is available with every element type or seal.
The catalogue has inconsistent element naming for option 90; confirm the exact element designation before ordering.
Source: RCSL Product Catalogue 2019, PDF pages 42, 43. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.
Discuss your requirements
Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.