RCSL Corrosion Monitoring

Model ER0500 – Electrical Resistance Probe

The ER0500 monitors corrosion in buried infrastructure, tanks, pipelines and structural applications. Surface-strip and cylindrical elements support demanding installations, with optional grounding connections for assessing cathodic-protection performance or environmental corrosivity.

Model ER0500 - Electrical Resistance Probe

Product information

View Model ER0500 – Electrical Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.

Technical information and selection

Specification Catalogue value
Surface-strip body PVC / epoxy
Standard cylindrical body FRP / epoxy
High-temperature cylindrical body Stainless steel
Standard cable jacket High-density polyethylene, rated for direct burial
High-temperature cable jacket Teflon FEP
Standard temperature rating 80°C / 176°F
High-temperature cylindrical rating 200°C / 392°F

Element options

Ordering option code Element and useful life
10 10 mil thickness (5 mil useful probe life) – cylindrical or surface strip
20 20 mil thickness (10 mil useful probe life) – cylindrical or surface strip
40 40 mil thickness (20 mil useful probe life) – surface strip only
50 50 mil thickness (25 mil useful probe life) – cylindrical only

Application and installation notes

  • A grounding lead allows connection to a cathodically protected structure to assess protection performance. Left unconnected, the probe measures the surrounding environment’s corrosivity.
  • Surface-strip and cylindrical designs are offered with or without grounding straps; a high-temperature cylindrical variant is also listed. Standard cable choices are 10 ft and 20 ft.
  • For CT50 carbon-steel cylindrical elements the catalogue specifies alloy code 378 rather than 375.

Element alloy options in the catalogue include carbon steel, 5Cr ½Mo, 9Cr 1Mo, 410 stainless, 304 stainless, 316L stainless, C276, Alloy 625, CDA110 and CDA443. Not every alloy is available with every element type or seal.

Source: RCSL Product Catalogue 2019, PDF pages 34, 35. Ratings and options are as published for the stated configurations; confirm the current specification, material compatibility and complete assembly rating before ordering.

Discuss your requirements

Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.

Contact Tremco Pipeline Equipment