RCSL Corrosion Monitoring

Two Inch System Retriever Unit

The RCSL Two Inch System Retriever Unit is used with a service valve to remove retrievable monitoring probes, coupon holders and chemical injection devices from pressurised pipelines or vessels. Its pressure-balanced design supports different device lengths and operating pressures.

RCSL Two Inch System Retriever Unit
Manufacturer illustration from the linked RCSL datasheet.

Pressure-balanced retrieval

The tool balances pressure across its internal surfaces during retrieval. RCSL lists stainless-steel-barrel options for 250 bar and 400 bar service, plus a lightweight aluminium-barrel option rated at 100 bar.

Selection and kit contents

Specify the required stroke, device length, plug type and removal clearance. Solid and hollow plug arrangements have different retrieval limits. Kits include a carrying case, maintenance tools, spare seals and an operation and maintenance manual; repair and seal kits are available separately.

These details summarise the linked RCSL Rev. 01 datasheet. Confirm current specifications and suitability before ordering. Only appropriately trained personnel should operate this equipment under manufacturer instructions and site procedures.

Product information

Review the manufacturer datasheet for dimensions, configurations and ordering information. Confirm current suitability and availability with Tremco before selection.

Two Inch System Retriever Unit manufacturer datasheet (PDF)

Operation and maintenance must follow the applicable manufacturer instructions and site procedures, by appropriately trained personnel.

Retriever size and ordering table

Dimensions below are reproduced in the catalogue units and apply only to 5.25-inch flare-weld and butt-weld access fittings. Solid and hollow plug limits differ. For injection, sampling and sand-probe systems, the associated nut length is included in device length. Obtain manufacturer confirmation for other fittings. A dash means the catalogue gives no code, not that an option is available.

Nominal stroke (in) Stroke (mm) Max solid-plug device (mm) Max hollow-plug device (mm) Collapsed (mm) Extended (mm) Removal clearance (mm) 100 bar code 250 bar code 400 bar code
12 305 76 51 496 804 1058 — 700631 —
14 355 127 102 546 905 1159 — 700599 —
18 457 228 203 648 1108 1362 700501 700601 700801
20 508 278 254 699 1210 1464 — 700632 —
25 630 406 381 826 1463 1713 700502 700602 700802
32 830 533 508 1003 1818 2069 700503 700603 700803
37 940 711 685 1130 2073 2323 700504 700604 700804
40 1016 838 813 1207 2226 2476 — 700597 —
42 1062 888 863 1257 2328 2578 — 700598 —
49 1224 1016 990 1435 2683 2937 700505 700605 700805
52 1321 1091 1065 1511 2835 2957 — 700585 —
62 1530 1320 1295 1740 3292 3546 700506 700606 700806

The nominal-inch and metric values are quoted as printed, not converted. Check the current dimensional drawing, particularly clearance, before installation.

Spare 250 bar / 100 bar 400 bar
Seal kit 700084 700084 [400bar]
Repair kit 700085 700085 [400bar]

Source: RCSL Product Catalogue 2019, PDF pages 11–12. Values describe the published manufacturer configuration; confirm current materials, ratings and compatibility before specification or ordering.

Discuss your requirements

Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.

Contact Tremco Pipeline Equipment