RCSL Corrosion Monitoring
Model LP7210 – Linear Polarisation Resistance Probe
The LP7210 positions three non-replaceable electrodes flush with the pipe wall through a two-inch access system. Retrievable construction allows installation under operating conditions using compatible retrieval equipment.
Product information
View Model LP7210 – Linear Polarisation Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.
Specifications and selection information
| Property | Details |
|---|---|
| Body | 316 stainless steel or C276 |
| Endcap seal / fill | Epoxy / epoxy |
| Temperature | 260°C / 500°F |
| Pressure | 3600 psi / 245 bar |
| Mounting | Two-inch access fitting with hollow plug |
| Connection | 1-14 UNS 2A left-hand thread; six-pin connector |
| Insertion length | Minimum 1.75 inches, specified in ⅛ inch increments |
| Electrodes | Three integral flush electrodes; not replaceable |
A compatible retriever and service valve allow installation through the access system without shutdown. Select the mounting alloy, fixed or adjustable flush configuration, electrode alloy and PTFE or PEEK probe seal. Confirm access-system compatibility before servicing.
Replacement parts
| Item | Code |
|---|---|
| PTFE probe seal | 700277 |
| PEEK probe seal | 700339 |
| 316 stainless hollow-plug bore-seal nut | 700311 |
Listed electrode alloy options
| Code | Alloy | UNS |
|---|---|---|
| 377 | C1018 carbon steel | G10180 |
| 159 | 316L stainless steel | S31603 |
| 419 | CDA110 | C11000 |
| 434 | CDA443 | C44300 |
Source: RCSL product catalogue, PDF pages 108, 109. Ratings depend on the selected configuration; confirm current suitability and documentation before ordering.
Discuss your requirements