RCSL Corrosion Monitoring

Model LP4100 – Linear Polarisation Resistance Probe

The LP4100 provides three-electrode LPR monitoring through a retractable packing-gland assembly. It supports insertion and withdrawal from pressurised process equipment, with selectable lengths and electrodes supplied separately.

RCSL Model LP4100 - Linear Polarisation Resistance Probe

Product information

View Model LP4100 – Linear Polarisation Resistance Probe on the RCSL website for manufacturer details. Check the current documentation for the selected model and configuration.

Specifications and selection information

Property Details
Body 316 stainless steel or C276
Seal / fill Glass / epoxy
Packing PTFE standard; Grafoil optional
Temperature 260°C / 500°F with PTFE
Pressure 2000 psi / 138 barg
Mounting Minimum 1 inch full-bore valve
Electrodes EL412XXX2800000; sold separately

Packing gland, mechanical stop and adjustable safety chain support retractable installation. RCSL recommends the SR2159 Easy Tool for insertion/retraction above 150 psi. External piping/valve components and electrodes are separate. Electrode alloy changes electrode length. Refer to the complete system procedure before pressurised servicing.

Standard lengths

Order length (inches) Maximum insertion length (inches)
24 17.53
30 23.53
36 29.53
42 35.53

Choose integral or plug-type mounting and the required packing. Optional safety-clamp code PS5463141XX uses XX for length.

Source: RCSL product catalogue, PDF pages 96, 97. Ratings depend on the selected configuration; confirm current suitability and documentation before ordering.

Discuss your requirements

Include the model, intended application, process conditions and existing connection details in your enquiry. Confirm suitability, the current manufacturer documentation and availability with Tremco before specifying or ordering equipment.

Contact Tremco Pipeline Equipment